In the process of a long-term continuous operation of an air compressor system, it is inevitable that you will encounter problems of all sizes. This time we will analyze the common problems and solutions of the safety valve of the air compressor equipment. Provide users with some ideas to solve the problem.

1. Leakage of the safety valve: The solution is to replace the spring in the valve, recall the original elasticity and reset the pressure;

2. The safety valve is at the rated pressure position and has not been opened. The reason is that there is adhesion between the disc and the seat of the safety valve. It is recommended to manually discharge the safety valve regularly;

3. The safety valve starts automatically before the rated pressure is reached, the same can be solved by the method of replacing the spring mentioned above;

4. After the air compressor discharges the gas, the exhaust pressure will only increase. In addition to replacing the old-fashioned spring, the exhaust pipe should also be replaced with a type that meets the safety area;

5. After the gas is discharged, the valve clack cannot return to the original position, or it is caused by the spring position not being straightened; the discharge pressure is caused;

6. The safety valve disc has a strong sense of vibration, mainly because the resistance of the pipeline exceeds the normal value. The method is to appropriately adjust the position of the adjusting ring and place it reasonably.